FUP 11 MS – Technical data

Drainage Pump

CAPACITY

l/min
0 60 120 180 240 300 360 420 480 540 600 660 720 780 840 900  
l/s
0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0 11.0 12.0 13.0 14.0 15.0  
m3/h
0 4 7 11 14 18 22 25 29 32 36 40 43 47 50 54  

TOTAL MANOMETRIC HEAD

m
13.3 12.4 11.5 11 10.2 9.2 8.5 7.7 7 6.2 5.5 4.8 3.5 2.6 2 1  

-H=UNI EN ISO 9906 < Sedimentation risk > Intermittent running

PUMP DATA

m 50 Hz 60 Hz
ØImpeller (mm) 118 -
Impeller blade height (mm) 13 13
Ø Free passage (mm) 6 6
Weight (Kg) 34 34

MOTOR DATA

m 50 Hz 60 Hz
PN / Rated power (kW) 1.1 1.1
P1 / Network absorbed power (kW) 1.7 1.7
P2 / Power at the motor shaft (kW) 1.3 1.3
ƞ/ Hydraulic efficiency (%) 48 48
Phases 3 3
Voltage (V) 400±10% 400±10%
Frequency (Hz) 50 60
Revolutions per minute (RPM) 2850 3390
Poles 2 2
Rated current (A) 3 3
Capacitor (µF) - -
Power factor (COSɸ) 0.8 0.8

Please note: Revision possible without prior notice.

Other Products From Clayton Engineering