FUP 11 MS – Technical data

Drainage Pump

CAPACITY

l/min
0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750  
l/s
0 0.8 1.6 2.5 3.3 4.2 5 5.8 6.6 7.5 8.3 9.2 10 10.8 11.6 12.5  
m3/h
0 3 6 9 12 15 18 21 24 27 30 33 36 39 42 45  

TOTAL MANOMETRIC HEAD

m
9,7 9.5 9.2 8.9 8.3 7.8 7.2 6.6 5.9 5.3 4.8 4 3.4 2.9 2.1 1.5  

-H=UNI EN ISO 9906 < Sedimentation risk > Intermittent running

PUMP DATA

m 50 Hz 60 Hz
ØImpeller (mm) 108 95
Impeller blade height (mm) 14,5 14,5
Ø Free passage (mm) 5 5
Weight (Kg) 23.5 23.5

MOTOR DATA

m 50 Hz 60 Hz
PN / Rated power (kW) 1,1 1,1
P1 / Network absorbed power (kW) 1,6 1,6
P2 / Power at the motor shaft (kW) 1,1 1,1
ƞ/ Hydraulic efficiency (%) 45 45
Phases 1 1
Voltage (V) 230±10% 230±10%
Frequency (Hz) 50 60
Revolutions per minute (RPM) 2820 3372
Poles 2 2
Rated current (A) 7.4 7.4
Capacitor (µF) 25 25
Power factor (COSɸ) 0.92 0.92

Please note: Revision possible without prior notice.