GV 2012-2 M S/A

Drainage Pump

CAPACITY

l/min
0 50 100 125 150 175 200 225 250 275 300 325 350 375 400 450  
l/s
0 0.8 1.6 2.1 2.5 2.9 3.3 3.8 4.2 4.6 5 5.4 5.8 6.3 6.6 7.5  
m3/h
0 3 6 7.5 9 10.5 12 13.5 15 16.5 18 19.5 21 22.5 24 27  

TOTAL MANOMETRIC HEAD

m
10 9.3 8.4 7.9 7.4 7 6.5 6.1 5.6 5.2 4.8 4.1 3.8 3.3 2.8 1.7

Q-H=UNI EN ISO 9906 < Sedimentation risk > Intermittent running

PUMP DATA

m 50 Hz 60 Hz
ØImpeller (mm) 111 96
Impeller blade height (mm) 14 14
Ø Free passage (mm) 46 46
Weight (Kg) 18.5 18.5

MOTOR DATA

m 50 Hz 60 Hz
PN / Rated power (kW) 0.9 0.9
P1 / Network absorbed power (kW) 1.4 1.4
P2 / Power at the motor shaft (kW) 0.82 0.82
ƞ/ Hydraulic efficiency (%) 31 31
Phases 1 1
Voltage (V) 230±10% 230±10%
Frequency (Hz) 50 60
Revolutions per minute (RPM) 2800 3360
Poles 2 2
Rated current (A) 7 7
Capacitor (µF) 25 25
Power factor (COSɸ) 0.96 0.96

Please note: Revision possible without prior notice.

Other Products From Clayton Engineering