RTL 2015-2M S/A Technical Data

Water Transfer Pump

CAPACITY

l/min
0 25 50 62.5 75 87.5 100 112.2 125 137.5 150 160 175 187.5 200 225  
l/s
0 0.4 0.8 1 1.3 1.5 1.6 1.9 2.1 2.3 2.5 2.7 2.9 3.1 3.3 3.8  
m3/h
0 1.5 3 3.7 4.5 5.2 6 6.7 7.5 8.2 9 9.6 10.5 11.2 12 13.5  

TOTAL MANOMETRIC HEAD

m
15.2 14.1 12.9 12.2 11.4 10.8 10 9.2 8.5 7.6 6.9 6 5.2 4.4 3.6 1.9  

-H=UNI EN ISO 9906 < Sedimentation risk > Intermittent running

PUMP DATA

m 50 Hz 60 Hz
ØImpeller (mm) 133 118
Impeller blade height (mm) 10 10
Ø Free passage (mm) 5 5
Weight (Kg) 29 29

MOTOR DATA

m 50 Hz 60 Hz
PN / Rated power (kW) 1.1 1.1
P1 / Network absorbed power (kW) 1.35 1.35
P2 / Power at the motor shaft (kW) 1 1
ƞ/ Hydraulic efficiency (%) 20 20
Phases 1 1
Voltage (V) 230±10% 230±10%
Frequency (Hz) 50 60
Revolutions per minute (RPM) 2820 3365
Poles 2 2
Rated current (A) 7 7
Capacitor (µF) 25 25
Power factor (COSɸ) 0.94 0.94

Please note: Revision possible without prior notice.