RW 4070-4T Technical Data

RW 4070-4T Technical Data

Drainage Pump

CAPACITY

l/min
0 200 400 600 800 1000 1100 1200 1300 1400 1500 1600 1700 1800 2000 2200  
l/s
0 3.3 6.6 10 13.3 16.6 18.3 20 21.6 23.3 25 26.5 28.3 30 33.3 36.6  
m3/h
0 12 24 36 48 60 66 72 78 84 90 96 102 108 120 132  

TOTAL MANOMETRIC HEAD

m
14.1 13.4 12.6 11.5 10.2 9 8.3 7.7 7 6.3 5.8 5.1 4.6 4 2.9 2  

-H=UNI EN ISO 9906 < Sedimentation risk > Intermittent running

PUMP DATA

m 50 Hz 60 Hz
ØImpeller (mm) 230 196
Impeller blade height (mm) 60 60
Ø Free passage (mm) 98 98
Weight (Kg) 143 143

MOTOR DATA

m 50 Hz 60 Hz
PN / Rated power (kW) 5 5
P1 / Network absorbed power (kW) 6.6 6.6
P2 / Power at the motor shaft (kW) 4.8 4.8
ƞ/ Hydraulic efficiency (%) 40 40
Phases 3 3
Voltage (V) 400±10% 400±10%
Frequency (Hz) 50 60
Revolutions per minute (RPM) 1450 1740
Poles 4 4
Rated current (A) 12 12
Capacitor (µF) - -
Power factor (COSɸ) 0.82 0.82

Please note: Revision possible without prior notice.